    Smoke Detector

    Function overview

    The Smoke Detector reliably protects against fire hazards.

    With multi-sensor technology, it distinguishes between fast-burning flames and smoldering fires while reducing false alarms caused by cooking smoke.

    • Wireless smoke detector with multi-sensor technology

    • Differentiates everyday smoke from real emergencies

    • Reduces nuisance alarms

    • Alerts with buzzer, LED, and Base Station signal

    • LED indicator

      • Red LED:

        • Quick flash: Alarm triggered

        • Flashes every second: Smoke detector in alarm silence mode

        • Flashes every 2 seconds: Warm-up phase / calibration

        • Flashes every 4 seconds together with orange: Low battery

        • Brief flash: When the Learn/Test button is pressed to check device function or for system pairing

        • 6 brief flashes: Signal is being transmitted

      • Orange LED:

        • Flashes every second: Calibration failed

        • Flashes every 4 seconds together with red: Battery exhausted

        • Flashes every 5 seconds: Smoke detection failed or device malfunction

        • Flashes every 45 seconds: Low battery

      • Test/Learn button:

        • Short press:

          • Send test signal

          • Check smoke chamber

          • Silence alarm (9 min.)

          • Pair with Base Station

        • Press and hold for 10 seconds:

          • Start calibration

    • Battery

      • Uses 3 × CR123 3V lithium batteries

      • Automatic battery check every 25 seconds

      • If battery is low: Orange LED + signal to base station + beep every 45 seconds

      • If battery is exhausted: Red + orange LEDs flash every 4 seconds

      • Replacement: Remove old batteries → wait 10 min → press button twice → insert new batteries

      Note:
      In low battery warning mode, the beep will be silenced for 7 days after the first button press. It cannot be muted again after that.

    • Dust detection

      • The detector regularly checks the optical chamber for excess dust

      • If dust is detected, it reports to the panel with a cleaning request

      • If the chamber isn’t cleaned and too much dust accumulates, a maintenance warning is issued

    • Supervision

      • The Smoke Detector sends periodic supervision signals to the Base Station

      • If no signal is received, the Base Station will indicate a fault

    • Alarm activation
      When smoke is detected, the alarm is triggered, a signal is sent to the base station, and the buzzer sounds.

    • Smoke detection

      • The smoke detector checks air quality every 8 seconds

      • If the smoke level exceeds the threshold, the alarm sounds and remains active until levels drop

      • The red LED flashes rapidly during alarm

    • Alarm silence

      • Pressing the test button during alarm will silence it for 9 minutes

      • The red LED flashes once per second. If smoke falls below threshold during silence, a two-tone beep sounds and normal mode resumes.

      • If smoke rises or exceeds a second threshold, the alarm will sound again and can no longer be silenced by the button.

    • Auto-Calibration

      • After first installation, auto-calibration runs after 4 hours, then every 15 days

      • During calibration, the red LED flashes (every 2 seconds, about 50 sec)

      • If calibration fails, the orange LED flashes every second and a fault is reported. Flashing can be stopped by removing/reinserting the batteries or by starting manual calibration

      • If calibration fails again, the orange LED will flash constantly and continuous beeping occurs—remove batteries briefly and reinsert

      Note: If auto-calibration fails, the alarm uses the last successful value. For best results, calibrate the detector at its permanent location.

    • Recalibration

      • Hold test button 10 sec., release at 2 beeps

      • After 5 sec. beep, calibration starts (red LED flashes every 2 sec.)

      • Lasts ~1 min; retries up to 9 min if fails

      • Success: Two-tone beep, red LED off, normal mode

      • Fail: Continuous beep + orange LED flashes

      • Remove battery → press test button twice → insert battery → restart

    Installation
    1
    Switch on
    • Insert batteries → beep + warm-up (1 min)

    • Automatic calibration (1–9 min)

    • Success: beep + LED off → normal mode

    • Calibration failed: remove batteries, press button 2×, reinsert

    2
    Registering with the App

    Follow the instructions in the app to add the Smoke Detector.


    3
    Alternatively: Add the Smoke Detector manually
    1. Put Base Station in pairing mode (press Reset/Learn 6 s until LED flashes blue)

    2. Press and hold LED Indicator on detector for 3 s (LED lights)

    3. Success = 1 beep from Base Station. If the Detector is not added within 25 seconds, please repeat the pairing process

    NOT AVAILABLE

    Tip:

    Name each detector uniquely for easy identification.

    4
    Placing/Mounting the Smoke Detector
    • Install on ceiling, preferably in room center, at least 60 cm away from walls

    • Avoid: kitchen, near fans, fluorescent lights, AC units, ceiling beams, over cabinets, or attic peaks

    • Recommended locations: open ceiling area with unobstructed view, near entrances

    • Avoid direct sunlight, heat sources, or moving objects

    • Ideal mounting height: about 3 meters; higher can affect detection

    • Use mounting template to mark holes, insert anchors, and screw in bracket

    Congratulations! The installation of your Smoke Detector is complete.

    Important notes

    • Test your Smoke Detector weekly using the test button to ensure it works properly.

    • Clean the detector at least every 6 months: gently vacuum dust from the detection chamber and vents.

    • Wipe the casing with a damp cloth, do not allow water inside. Avoid using cleaning agents.

    • Avoid spraying aerosols such as air fresheners or hairspray near the detector.

    • Never paint or modify the detector.

    • The smoke detector has a maximum lifetime of 10 years. Replace it immediately after this period.

    • A replacement date should be marked on the back of the detector.

    Setting from device

    Alarm silence, manual calibration

    Button functions

    Test / Learn / Silence

    Siren output

    85 dB at 3 m

    Power source

    3x CR123 lithium batteries

    Battery life

    10 years (actual battery life may vary depending on settings, the environment and usage)

    Low battery threshold

    2.7 V

    Frequency

    868 MHz

    Range

    300 metres in open space

    Operating temperature

    –10°C to +45°C

    Operating humidity

    85% relative humidity @ 23°C (non-condensing)

    Dimensions

    106.4 × 106.4 × 45.5 mm

    Weight

    190.5 g (battery excluded)